BF135A•BF150A -2. Check for the continuity between the IAC valve No. 2 terminal and the body ground. • VTEC Solenoid Valve Troubleshooting MIL blinks 21 times 1. Spool solenoid valve check -1. Turn the ignition switch OFF and disconnect the spool solenoid valve connector. -2. Measure the resistance between the spool solenoid valve side 1P connector terminal (Green/White) and the body ground. IAC VALVE SIDE 2P CONNECTOR VIEWED FROM THE TERMINAL SIDE SPOOL SOLENOID VALVE SIDE 1P CONNECTOR Is there the continuity? YES – Replace the IAC valve. NO – Perform "4. IAC valve line open circuit check". 4. IAC valve line open circuit check -1. Connect the IAC valve 2P connector. -2.
Disconnect the ECM connector B. -3. Measure the resistance between the test harness B-26 terminal and the B-34 terminal. VIEWED FROM THE TERMINAL SIDE Is the measured resistance 12 – 18 ? YES – Perform "2. VTEC signal line short circuit check". NO – Replace the spool solenoid valve. B-26 B-34 2. VTEC signal line short circuit check -1. Turn the ignition switch OFF and connect the test har- ness. Hold the ECM connector A disconnected. -2. Check for the continuity between the test harness A-20 terminal and the engine ground. Is the resistance 10 – 13 ? YES – Perform "5. IAC valve line short circuit check". NO – Check for open in the wire between the ECM and the IAC valve. 5.
IAC valve line short circuit check -1. Check for the continuity between the test harness B-26 terminal and the engine ground, and between the B-34 terminal and the engine ground. A-20 Is there the continuity? YES – Repair short in the wire between the ECM and the spool solenoid valve. NO – Perform “3. VTEC signal line open circuit check”. B-26 B-34 Is there the continuity? YES – Repair short in the wire between the ECM and the IAC valve. NO – Substitute a known-good ECM and recheck. 5-82