BF135A•BF150A 10.IAB (Intale Air Bypass) CONTROL SYSTEM 3. IAB control valve check -1. Connect the vacuum tubes. -2. Disconnect the IAB control valve 2P connector while running the engine at idling. -3. Check the vacuum tube located above the IAB control valve for vacuum. • IAB Control Valve Inspection 1. Vacuum line check -1. Check the vacuum tubes between the shutter valve diaphragm and IAB control valve, and between the solenoid valve and intake manifold. Is there the vacuum? YES – Perform "4. Ground line short circuit check". NO – Replace the IAB control valve. SHUTTER VALVE DIAPHRAGM 4. Ground line short circuit check -1. Turn the ignition switch OFF.
Disconnect the ECM con- nector A and the IAB control valve 2P connector. -2. Check for the continuity between the No.2 (Black) ter- minal of the IAB control valve harness side 2P con- nector and the engine ground. IAB CONTROL VALVE HARNESS SIDE 2P CONNECTOR BLACK INTAKE MANIFOLD VACUUM TUBE Are the tubes disconnected, torn or clogged? YES – Replace the vacuum tubes. NO – Perform "2. Operation check at idling". VIEWED FROM THE TERMINAL SIDE Is there the continuity? YES – Repair short in the wire between the ECM and the IAB control valve. NO – Substitute a known-good ECM and recheck. 2. Operation check at idling -1. Start the engine and let it warm up. Run the engine at idling. -2.
Disconnect the vacuum tube from the shutter valve diaphragm, and check the vacuum. 5. Operation check at engine stop and at high engine speed -1. Start the engine and run it at idling. Stop the engine and check the shutter valve diaphragm side vacuum tube for the vacuum. Is there the vacuum? YES – Perform “5. Operation check at engine stop and at high engine speed”. NO – Go to the step 3. Is the vacuum removed? YES – Perform shutter valve diaphragm check (P. 5- 110). NO – Perform "6. Signal line open circuit check". -3. Disconnect the vacuum tube underside the IAB control valve, and check the vacuum. Is there the vacuum? YES – Perform "3. IAB control valve check".
NO - • Faulty vacuum chamber • Faulty check valve 5-109