BF135A•BF150A b. REPLACEMENT 1) Disconnect the low pressure side EOP switch terminal. 2) Remove the EOP switch. 3) Clean the EOP switch installation section in the crankcase. 4) Apply the liquid gasket (ThreeBond ® #1215 or equivalent) to the indicated area of the threads of the new EOP switch. [1] EOP SWITCH 5) Install and tighten the EOP switch to the specified torque. TORQUE: 8 N m (0.8 kgf m, 6 lbf ft) NOTICE Be sure to use the torque wrench to tighten the EOP switch. Do not exceed the specified torque when tightening the EOP switch. Overtightening will damage the cylinder block. 6) Connect the EOP switch terminal. [1] LIQUID GASKET APPLICATION AREA 18.
ECT (ENGINE COOLANT TEMPERATURE) SENSOR 1 [1] 13 x 1.5 mm O-RING [2] ECT SENSOR 1 CONNECTOR Do not reuse. a. REPLACEMENT 1) Disconnect the 2P connector of ECT sensor 1. 2) Remove the ECT sensor 1 and the O-ring. Replace the O-ring on assembly. 3) Apply the engine oil to the new O-ring and install it on the ECT sensor 1. 4) Tighten the ECT sensor 1 to the specified torque. TORQUE: 12 N m (1.2 kgf m, 9 lbf ft) [3] ECT SENSOR 1 5) Connect the ECT sensor 1 connector. 5-147