honda — Electrical Equipment

Use a known-good battery. NOTICE 2) Connect the wires as shown, and check for continuity between the following terminals. Connecting positive (+) battery terminal to Light green terminal: Bu Lb Lg Connecting positive (+) battery terminal to Light blue terminal : [1] Connect the (+) battery terminal. G W Bl 18-30 Green to Black terminals No continuity Blue to Black terminals Continuity Green to White terminals Continuity Blue to White terminals No continuity Green to Black terminals Continuity Blue to Black terminals No continuity Green to White terminals No continuity Blue to White terminals Continuity