JCB — Refrigerant Charging and Discharging

A396790 Electronic Vacuum Gauge The CPS VG100 vacuum gauge is an electronic type using LED’s to indicate various states of vacuum. It is used in place of or to supplement the gauge on the vacuum pump. Before connecting into the system switch on to check that the first LED lights to show that the battery is in good condition. Note: The indicator lights show pressure in inches of mercury (Hg) and vacuum in microns (0.001mm Hg). ATM/BAT Normal atmospheric pressure reading. Battery condition. 15’’/510mbar 381mm (15 in)Hg. Partial vacuum - Vacuum system is operating. 29’’/980mbar 736mm (29 in)Hg. No vacuum drawn - Possible system leakage. 8000µ 8.0mm (0.31 in)Hg.

Partial vacuum - If the reading does not progress the system may have a slow leak. 1000µ 1.0mm (0.039 in)Hg. Deeper vacuum. 600µ 0.6mm (0.023 in)Hg. Deep vacuum. 400µ 0.4mm (0.015 in)Hg. Deep vacuum. 200µ 0.2mm (0.0078 in)Hg. Deep vacuum. 25µ 0.025mm (0.00098 in)Hg. Pump Test. Maximum sustainable vacuum. 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section B Body & Framework Section B 20 - 4 20 - 4 Service Procedures