JCB — Refrigerant Charging and Discharging

Air Conditioning - Refrigerant Charging and Discharging Note: The procedures for refrigerant charging and discharging must only be carried out by qualified service personel who have received specialist training on the air conditioning system. ! WARNING The air conditioning system is a closed loop system and contains pressurised refrigerant. No part of the system should be disconnected until the system has been discharged by a refrigeration engineer or a suitable trained person. You can be severely frostbitten or injured by escaping refrigerant. 4-3-4-1/2 Relubricating Pre-lubrication is essential after recovering system refrigerant, vacuuming and component flushing.

The system should be evacuated to a vacuum of 740mm (29 in) of mercury before re-lubricating. Lo Hi 1 Ensure that the engine is OFF and the starter key is removed. To system Low Pressure port. Valve OPEN To system High Pressure port. Valve OPEN 2 Close all valves and connect the manifold as shown, with the blue hose connected to the oil injector and the red hose to the system high pressure port. 3 Connect the yellow hose to the vacuum pump. 4 Connect the other end of the oil injector to the system low pressure point. Oil Injector Vacuum Pump 5 Switch on the vacuum pump and open the high pressure side valve. To system Low Pressure port. Oil injector valve - Open when full vacuum is obtained.

6 Unscrew the oil injector cap and add the specified quantity of refrigerant oil. 7 When 740mm (29 in) mercury shows on the vacuum gauge, open the oil injector valve to allow the oil into the system. A396800 8 If more oil is needed repeat the above procedure. The quantity of oil should be the same as that taken out during the ‘ Recovery ’ procedure. Notes: Use only PAG oil in R-134a systems. 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section B Body & Framework Section B 20 - 5 20 - 5 Service Procedures