Mitsubishi SA6D125 — FUEL INJECTION PUMP CALIBRATION DATA

TESTING AND ADJUSTING FUEL SYSTEM (CALIBRATION DATA) 615002 12-12-16 8 5 12-12-16 (10) Injection Pump Assembly Number Applicable Machine Applicable Engine 6151-72-1390 (106692-9280) Model Serial No. Model Serial No. ( ): Injection pump manufacturer’s part No. For MQ generator S6D125-2 Injection Injection pump DCA-220 SSK Pump Type Manufacturer (Prime) PE-P(PS3S) BOSCH Injection pump specification Engine Specification Rotating direction Counterclockwise Flywheel horsepower (kW {HP}) / rpm) 209 {280}/1,800 (60 Hz, Gross) Injection order 1 – 5 – 3 – 6 – 2 – 4 Maximum torque (Nm {kgm}/ rpm) — Injection interval 59°30’ – 60°30’ High idling speed (rpm) Max.

1,890 (60 Hz) Plunger pre-stroke (mm) 3.59 – 3.65 Low idling speed (rpm) 700 – 800 Delivery valve (mm3/st) 90 Pump tester capacity retraction volume Motor 7.5 kW for Service standard Calibration Standard ( ): Injection pump manufacturer’s part number Applicable Machine Applicable Engine Model Serial No. Model Serial No. For MQ generator DCA-220 SSK (Prime) S6D125-2 Conditions Nozzle & nozzle holder part No. Nozzle part No. ‡ Service standard indicates data Nozzle holder part No. using calibration Injection pipe (mm) test parts. (Outside dia. x inside dia. x length) ‡ Manufacturer Test oil standard is data Oil temperature (°C) for factory test.

Nozzle opening pressure (MPa{kg/cm2}) Transfer pump pressure (kPa{kg/cm2}) Service standard Manufacturer standard Nozzle & nozzle holder part No. (105780-8140) 6151-12-3300 (105111-4570) Nozzle part No. (105780-0000) 6151-12-3320 (105025-0690) Nozzle holder part No. (105780-2080) 6152-12-3110 (105041-7130) Injection pipe (mm) (Outside dia. x inside dia. x length) 8 x 3 x 600 6 x 2.2 x 720 Test oil ASTM D975 No. 2 diesel fuel or equivalent Oil temperature (°C) 40 to 45 Nozzle opening pressure (MPa{kg/cm2}) 17.2 {175} 24.5 {250} Transfer pump pressure (kPa{kg/cm2}) 157 {1.6} 157 {1.6} Injection volume ‡ Rack positions B to E are the reference volume when adjusting the injection volume.

Rack point Rack position (mm) Pump speed (rpm) Service standard (cc/1000 st.) Manufacturer standard (cc/1000 st.) Average injection quantity Maximum variance between cylinder Average injection quantity Maximum variance between cylinder A (Basic point) 10.3 750 208 – 212 ±3 230 – B Approx. 5.9 375 13.5 – 16.5 ±15 15 – C D E Governor performance curve Injection Pump Typ Injection pump e Manufacturer PE-P(PS3S ) BOSCH Flywheel horsepower (kW {HP}) / rpm) 209 {280}/1,800 (60 Hz, Gross) Maximum torque (Nm {kgm}/ rpm) — High idling speed (rpm) Max. 1,890 (60 Hz) Low idling speed (rpm) 700 – 800 Pump tester capacity for Service standard Motor 7.5 kW