TESTING AND ADJUSTING FUEL SYSTEM (CALIBRATION DATA) Injection Pump Assembly Number 615002 12-12-17 8 (10) 6152-72-1440 (106675-4172) Applicable Machine Applicable Engine 6152-72-1441 (106675-4173) 6152-72-1442 Model Serial No. Model Serial No. ( ): Injection pump manufacturer’s part No.
WA470-3 SA6D125-2 Injection Injection pump Pump Type Manufacturer PE-6P BOSCH Injection pump specification Engine Specification Rotating direction Counterclockwise Flywheel horsepower (kW {HP}) / rpm) 202 {275}/2,200 (Gross) Injection order 1 – 5 – 3 – 6 – 2 – 4 Maximum torque (Nm {kgm}/ rpm) 1,070 {109}/1,400 (Gross) Injection interval 59°30’ – 60°30’ High idling speed (rpm) 2,350 – 2,450 Plunger pre-stroke (mm) 3.75 – 3.85 Low idling speed (rpm) 700 – 750 Delivery valve (mm3/st) 100 Pump tester capacity retraction volume Motor 7.5 kW for Service standard Calibration Standard ( ): Injection pump manufacturer’s part number Applicable Machine Applicable Engine Model Serial No.
Model Serial No. A470-3 S A6D125-2 Conditions Nozzle & nozzle holder part No. Nozzle part No. ‡ Service standard indicates data Nozzle holder part No. using calibration Injection pipe (mm) test parts. (Outside dia. x inside dia. x length) ‡ Manufacturer Test oil standard is data Oil temperature (°C) for factory test. Nozzle opening pressure (MPa{kg/cm2}) Transfer pump pressure (kPa{kg/cm2}) Service standard Manufacturer standard nozzle holder part No. (105780-8140) 6152-12-3120 (105125-0120) art No. (105780-0000) 6152-12-3110 (105041-7130) older part No. (105780-2080) pipe (mm) dia. x inside dia. x length) 8 x 3 x 600 6 x 2.2 x 720 ASTM D975 No.
2 diesel fuel or equivalent erature (°C) 40 to 45 ening pressure (MPa{kg/cm2}) 17.2 {175} 27.5 {280} pump pressure (kPa{kg/cm2}) 157 {1.6} 157 {1.6} Injection volume Rack point ‡ Rack positions B to E are the reference volume A when adjusting (Basic poi the injection B volume. ‡ Marks fl are C average volumes.
D E Rack Pump position speed (mm) (rpm) Service standard (cc/1000 st.) M anufacturer standard (cc/1000 st.) Injection volume Maximum variance between cylinder Injection volume Maximum variance between cylinder 8.5 1,100 nt) fl142 – 146 ±3 fl155 – 9.1 700 fl162.5 – 168.5 – fl168.5 – 5.7 400 fl9.5 – 12.5 ±15 fl16.5 – – – – – – – 10 – 10.2 100 fl155 – 175 – fl160 – Governor performance curve Boost compensator performance curve Rotating direction Counterclockwise Injection order 1 – 5 – 3 – 6 – 2 – 4 Injection interval 59°30’ – 60°30’ Plunger pre-stroke (mm) 3.75 – 3.85 Delivery valve (mm3/st) retraction volume 100