Doosan G643 LP Engine — Doosan G643 LP Engine User Manual

Inspection of EST Distributor Description The Delco EST ignition system consists of the distributor, ignition coil, wiring and spark plugs. The distributor contains a module, pickup coil and conventional cap and rotor. There are no points or condenser to adjust or change and no moving parts except for the distributor shaft and rotor. Spark advance and dwell are controlled by the distributor module. The distributor module and pickup coil are self-contained solid-state devices which are not repairable. If necessary, they may be replaced separately but must be serviced as a complete unit.

Delco Distributor Component Testing NOTICE In the test procedures that follow, check the ignition coil and each component of the distributor separately to identify defective or good components. These tests can be made with the distributor and coil mounted on the engine or on the repair bench. Delco Distributor Module Testing NOTICE An approved module tester must be used in order to check the module. Use a Kent-Moore Module Tester or equivalent. 1. Remove module from distributor. 2. Connect red battery-cable clamp to positive (+)terminal and black battery-cable clamp to negative(-) terminal of a fully charged 12V battery. 3.

Connect the adapter to yellow 2-way terminal connector, and the adapter to black 3- wayconnector of the tester (IAGS054S). 4. Connect black 4-way and 2-way connectors to module terminals. Connect yellow 2-way connector to yellow module terminals and engage locking tabs. 5. Connect module ground clip of the tester to the metal base of the module. 6. Hold the toggle switch in the 3-terminal test position. If a momentary indication of the red "Fail" light and then a steady indication of the green "Pass" light occurs, go on to the next step. If a steady indication of the red "Fail" light occurs, the module is defective and should be replaced. 7. Disconnect black 4-way connector from module.

Disconnect yellow 2-way connector, rotate it 180 degrees so the lock and tab are opposite each other, and reconnect it to the module terminals (IAGS058S). 8. Hold the toggle switch in the 3-terminal test position. A momentary indication of the red "Fail" light and then a steady indication of the green "Pass" light mean the module is good. A steady indication of the red "Fail" light means the module is defective and should be replaced. G643(E) Service Manual Chapter 4. Engine Electrical System 118