Doosan G643 LP Engine — Doosan G643 LP Engine User Manual

Circuit Diagram (G643) OxygenSensor (Pre-Catalyst) [G643E] Component Location Pre - Catalyst Oxygen Sensor Description The heated oxygen sensor is mounted on the front side of Catalytic Muffler, which detects the oxygen concentration in the exhaust gas. The heated oxygen sensor produces a voltage that varies between 0V and 1V. When the air/fuel ratio is lean, the oxygen concentration in the exhaust gas increases and the front HO2S outputs a low voltage (approximately0~0.1V). When the air/fuel ratio is rich, the oxygen concentration in the exhaust gas decreases and the front HO2S outputs a high voltage (approximately0.8~1V).

The ECM constantly monitors the HO2S and increases or decreases the fuel injection duration by using the HO2S signal, which is called closed-loop fuel control operation. Sensor Inspection 1. Using a multimeter, measure the IAT sensor resistance between terminals 3 and 4. Specification 2. If the resistance deviates from the standard value, replace the intake air temperature sensor assembly. G643(E) Service Manual Chapter 5.

Engine Management System (EMS) 185 IG.SW.ON Temperature ℃ (°F) Resistance(kΩ) 0 (32) 4.5 ~ 7.5 20 (68) 2.0 ~ 3.0 40 (104) 0.7 ~ 1.6 80 (176) 0.2 ~ 0.4 Temperature Front HO2S Heater Resis- tance(Ω) Temperature Front HO2S Heater Resistance (Ω) (℃) (℉) (℃) (℉) 20 68 9.2 400 752 17.7 100 212 10.7 500 932 19.2 200 392 13.1 600 1,112 20.7 300 572 14.6 700 1,292 22.5