Removal and Installation of N-2007 LP Regulator Follow the procedures below for removal and reinstallation of the N-2007 regulator in certified systems. N-2007 Removal Steps Refer to Figure 28. 1. Close the liquid outlet valve in the forklift cylinder or fuel storage container. 2. Purge the system of fuel by starting the engine and running until all trapped fuel in the system is exhausted and the engine shuts down. 3. Key switch in “OFF” position. 4. Remove the fuel inlet line (1) from the lock-off, the two vacuum lines (2) from the branch-tee fitting in the regulator vent and disconnect the lock-off connector (3). 5.
Remove the four rear-mounting bolts that hold the regulator to the support bracket. This will allow easier access to the remaining hose clamps. 6. Remove the two cooling lines (4) and a thermostat (7) from the regulator. NOTE: Either drain the coolant system or clamp off the coolant lines as close to the regulator as possible to avoid a coolant spill when these lines are disconnected. 7. Remove the fuel vapor outlet hose (5) from the regulator. 8. Remove the nipple extension (6) with the lock-off from the regulator. Figure 28. N-2007 Regulator in Certified System N-2007 Installation Steps Refer to Figure 28. 1. Install the nipple extension (6) with the lock-off to the regulator. 2.
Install the fuel vapor outlet hose (5) to the regulator. 3. Install the two cooling lines (4) and a thermostat (7) to the regulator. 4. Install the four rear-mounting bolts that hold the regulator to the support bracket. Use a torque wrench and tighten each bolt to 60-70 lbf•in (6.78- 7.91 N· m). 5. Install the fuel inlet line (1) to the lock-off, the two vacuum lines (2) to the branch-tee fitting in the regulator vent and re-connect the lock-off connector (3). 6. Open the liquid outlet valve in the forklift cylinder or fuel storage container. G643(E) Service Manual Chapter 6. LPG FUEL DELIVERY SYSTEM 196