6. If present, set fuel select switch to LPG fuel. When operated at the factory, it is critical to simulate the airflow found on a forklift at idle as nearly as possible in order to achieve the proper air valve lift in the mixer. It may be necessary to place a load on the engine to achieve the required airflow without overspeeding the engine. Means of achieving this load include: a) Place an electrical load on the alternator. The alternator should be able to briefly hold loads of approximately 1.2 kW. b) Attach the engine to a dynamometer. Attach the Mototune Service Tool to the wiring harness and add parameter MAFPort to the display screen. Factory Adjustment Procedure: NOTE :
Be sure engine is fully warm (ECT>167°F [75°C]) before performing the idle mixture adjustment. 1. Operating the engine on LPG fuel, start the engine and permit the engine to warm up until the coolant temperature (ECT on Mototune display) is approximately 167°F (75 oC). 2. Set APP input to minimum. 3. Adjust the load until engine speed reaches 750 rpm. 4. Mototune display parameter LP Fuel Control must display “Closed Loop.” 5. Use the Mototune Service Tool to monitor Duty Cycle % on the Mototune display. 6. To adjust the idle mixture screw, use a 5mm hex or Allen-type wrench.
Turning the screw in (clockwise) should increase the duty cycle; turning the screw out (counter-clockwise) should decrease the duty cycle. 7. Adjust the idle mixture screw on the mixer until a reading of 40-45% is reached for the FTV Duty Cycle in Closed Loop Idle (Figure 35). Figure 41. FTV Duty Cycle Percentage Displayed on Service Tool 8. Use the accelerator pedal to increase RPM above idle momentarily (rev the engine) then release the pedal to return to idle RPM. The duty cycle setting should remain within the adjustment range (40- 45%).
Place your thumb over the adjustment port for a more accurate reading by preventing air from leaking past the mixture adjustment screw, which may cause the duty cycle to decrease. 9. Use the Mototune Service Tool to lock the FTV duty cycle. Set display parameter DitherValveDC_ovr = locked (displayed in screen tab Manual Override 1 under AFR Trim Vales, select “locked” under box labeled Lock DC%). 10. Use the Mototune Service Tool to monitor throttle position (TPS1) and Exhaust gas oxygen equivalence ratio (“O2 Value” in Figure 1). While monitoring O2, slowly increase the pedal input (APP) to achieve a TPS1 value of 15%. 11. Use the Mototune Service Tool to unlock the FTV duty cycle.
Set display parameter DitherValveDC_ovr = unlocked (displayed in screen tab Manual Override 1 under AFR Trim Vales, select “unlocked” under box labeled Lock DC%). 12. If at any time in step 10, O2 was greater than 1.2 go to step 13. If 02 remained below 1.2, proceed to Step 15. 13. Adjust the idle mixture screw on the mixer until a reading of 50-55% is reached for the FTV Duty Cycle in Closed Loop Idle (Figure 35). G643(E) Service Manual Chapter 6. LPG FUEL DELIVERY SYSTEM 202