Doosan G643 LP Engine — Doosan G643 LP Engine User Manual

Pressure Test Primary Stage Test Hardware 1. Hand vacuum pump 2. Regulator fuel inlet test fitting 1/4 NPT standard air coupling) 3. Test gauge fitting (1/4” NPT X 1/4” hose b) 4. Vacuum hose or vinyl tubing 5. 0-60” WC Magnehelic gauge (inches of water column) Figure 31. Primary Stage Test Connection Primary Stage Pressure Test 1. Remove the primary test port plug from the side of the regulator and install the 1/16” NPT hose barb fitting (Figure 31). 2. Connect a compressed air line (shop air ~100 psi) to the liquid propane fuel inlet of the N-2001 regulator (Figure 31). Figure 32. Magnehelic Gauge Connection to Hose Barb 3.

Apply compressed air, wait for air to exit the hose barb in the test port, and then connect the Magnehelic gauge (Figure 32) to the hose barb using the vacuum hose or vinyl tubing. This prevents the gauge from reading maximum pressure due to the large velocity of compressed air entering the primary chamber. 4. Make sure there is no leakage at any of the fittings. The static pressure should read between 40-60” WC on the Magnehelic gauge and maintain a constant pressure for 60 seconds. 5. If the pressure reading begins to increase, a leak is most likely present at the primary valve, either the primary valve o-ring or the valve itself. If a leak is present the regulator should be replaced. 6.

If the pressure begins to decrease, the secondary seat is probably not making an adequate seal and is leaking. The regulator should be replaced. 7. If the test is successful, re-install the primary test port plug and check the fittings for leaks. See Chapter 5 for installation of the N-2001 regulator. NOTE : The N-2001 primary stage pressure can also be tested at idle on a running engine. The N- 2001 primary pressure should be between 40 inH20 (99.635 mbar) and 55 inH20 (136.999 mbar) at 750 rpm, idle. G643(E) Service Manual Chapter 6. LPG FUEL DELIVERY SYSTEM 215