Doosan G643 LP Engine — Doosan G643 LP Engine User Manual

AVV (Air Valve Vacuum) Testing Purpose of Test Check for excessive or inadequate pressure drop across CA100 mixer. AVV Test Hardware 1. Union Tee fitting, 1/4” (6.35mm) NPT with three 1/4” (6.35mm) NPT x 1/4” (6.35mm) hose barbs 2. Vacuum hose 3. 0-20” H2O differential pressure Magnehelic gauge AVV Test 1. Install Union Tee fitting in the hose between the FTVs and the AVV fitting. Connect this fitting to the low pressure port of the Magnehelic gauge (Figure 37). 2. Leave high pressure port of the Magnehelic gauge exposed to ambient pressure (Figure 37). 3. With the engine fully warmed up and running at idle (750 rpm) place the transmission in Neutral.

The AVV should be between 5” and 8” H2O of pressure vacuum. 4. If the measured pressure drop is excessively high, check for sticking or binding of the diaphragm air valve assembly inside the mixer. Replace mixer if necessary. 5. If the measured pressure drop is low, check for vacuum leaks in the manifold, throttle, mixer, TMAP sensor and attached hoses. Figure 37. Magnehelic Gauge Connection Ignition Timing Adjustment With the MI-07 system, ignition-timing advance is controlled by the SECM. The initial ignition timing setting of the distribytor is described in chapter 4 Ignition System. Idle Mixture Adjustment NOTE :

Be sure engine is fully warm (ECT>167°F [75°C]) before performing the idle mixture adjustment. G643 LP Fuel Systems with O2 Sensor Idle Adjustment 1. Install mixer and a UEGO or HEGO sensor. (A UEGO sensor should be used when desired phi settings are not at stoichiometric.) 2. After the mixer is installed, start and warm up the engine to normal operating temperature (ECT>167°F [75°C]). Also ensure that the vehicle drive train and hydraulic systems are at normal operating temperatures per vehicle manufacturer recommendations. 3. Allow the engine to reach steady state at idle. 4.

While monitoring the output of the UEGO or HEGO sensor adjust the idle screw using a standard screwdriver until the desired phi reading is achieved (phi = 1.00 to 1.01 is optimal). To make the mixture richer, turn the screw clockwise; to make the mixture leaner, turn the screw counter-clockwise. 5. Rev the engine to take it off of idle and let it return to idle. 6. Once the engine has reached steady state at idle, verify the phi reading. Adjust further as needed. G643(E) Service Manual Chapter 6. LPG FUEL DELIVERY SYSTEM 216