MAINTENANCE 20.2.3 ANTIFEEZE Low silicate ethylene glycol antifreeze is recommended. The antifreeze should contain no more than 0.1% anhydrous alkali metasilicate. Low silicate antifreeze is recommended to avoid the formation of silica-gel (hydro-gel). This gel formation can occur when the cooling system contains an over concentration of high silicate antifreeze and or supplemental coolant additive. DO NOT use methanol or alcohol as an antifreeze because of its low boiling point. Antifreeze may retain its freeze protection for more than one season but coolant conditioners must be added to maintain corrosion protection.
Antifreeze formulated with methoxy propanol, or propylene glycol, is not recommended for this system. REMARK Do not mix types of antifreeze solutions. Mixed solutions make it impossible to determine the protection against freezing. Antifreeze containing sealer or antileak additives should NOT be used in this system. Sealer or antileak additives will cause plugging problems in the cooling system. A WARNING Use extreme caution when adding coolant to a hot radiator to avoid being burned. Wear gloves and goggles and keep face away from the filler neck. Check the solution periodically and at normal operating temperature, to be sure the cooling system has sufficient protection against freezing.
An antifreeze concentration greater than 68% will adversely affect freeze protection and heat transfer rates. Antifreeze concentrations between 68% and 100% actually have a higher freezing point than a 68% antifreeze concentration and should not be used due to reduced heat transfer rates. REMARK Do not use a 100% antifreeze solution for freezing protection, This will cause severe corrosion in the cooling system and if not detected will cause radiator and oil cooler core damage. Use a water/antifreeze solution as described in the following table. The following table shows the approximate percentage of antifreeze solution required for various temperatures.
Approximate Freezing Point Percentage of Antifreeze Concentration by Volume Specific Gravity at 16°C (60°F) 0°C (+32”F) 0 1 .ooo -7°C (+2O”F) 15 1.025 -12°C (+lO”F) 25 1.040 -23°C (-10°F) -18°C (0°F) 40 33 1.053 1.062 -29°C (-20°F) 45 1.070 -34°C (-30°F) -40°C (-40°F) 48 53 1.080 1.074 -46°C (-50°F) 56 1.083 -51 “C (-60°F) 59 1.088 -62°C (-80°F) -57°C (-70°F) 62 65 1.092 1.095 -68°C (-90°F) 67 1.097 -96°C (-92°F) 68 1.098 3-12