Alternator GENERAL The alternator requires no lubrication since its bearings are factory lubricated for life and require attention only at time of major overhaul. The alternator is equipped with an integral, transistorized voltage regulator. If the alternator fails to operate properly, consult your authorized Komatsu distributor. REMARK The unit electrical system is negative ground. Be certain the ground polarity is correct when installing a new battery, connecting a battery charge or using a booster. Failure to observe proper polarity will result in damage to the alternator. + NEVER use a fast charger as a booster to start the engine.
RED + NEVER turn OFF the electrical system master switch or unhook a battery terminal while the engine is running. + NEVER disconnect the alternator cable while the engine is running. CONNECTIONS Be sure the terminals on the back of the alternator are clean and the cables are fastened securely to the proper terminals as shown. Cranking Motor Should it become necessary to remove the motor in the process of engine servicing, tag all disconnected cables for ease of correct installation. 1. Disconnect all electrical cables and remove cranking motor. Clean outer surfaces. 2. Saturate all wicks and lightly lubricate the splines underneath the clutch housing with clean engine oil. R 3.
Install the cranking motor and connect all electrical cables. Tighten the cranking motor mounting bolts. If the cranking motor fails to operate properly, consult your autho- rized Komatsu distributor. BATTERY CABLE 3-59