Komatsu — 12.3.2 IN COLD AREAS (AUTOMATIC WARM UP OPERATION)

OPERATION idle continuously for more than 20 minutes. This will cause leakage of oil from the turbocharger oil supply piping. If it is necessary to run the engine at idling, apply a load from time to time or run the engine at a midrange speed. 1. Set fuel control dial (1) to the low idle (MIN) position and run the engine for about 5 minutes without load. 2. Press working mode switch (2) on the monitor panel until the H/O (heavy-duty operation) mode light illuminates. 3. Turn fuel control dial (1) to the medium speed position. 4. Set safety lock lever to the FREE position and raise the bucket from the ground. 2-60