Komatsu — 24.2.2 CLEAN INSIDE OF COOLING SYSTEM

MAINTENANCE Mixing Rate of Water and Antifreeze WARNING Antifreeze is flammable, so keep it away from any flame. ! Use city water for the cooling water. For water requirements, See 20.6 COOLANT on page 3-12 WARNING When removing drain plug, avoid pouring coolant on yourself. ! Stop the machine on level ground when cleaning or changing the coolant. ! Prepare a container to catch drained coolant: Coolant catch container . . . . . . . . . . . . Min 24 R capacity Draining System 1. Turn radiator cap (2) slowly to remove it. REMARK Open the cab heater valves at the engine. 2. Remove the undercover, then set a container to catch the coolant from drain valve (3) and drain plug (4).

Open drain valve (3) at the bottom of the radiator to drain the coolant. Remove drain plug (4) in the cylinder block to drain the coolant. 3. After draining the coolant, close drain valve (3) and drain plug (4) and fill with water. 3-28 Approximate Freezing Point Percentage of Antifreeze Concentration by Volume Specific Gravity at 16EC (60EF) 0EC (+32EF) -7EC (+20EF) -12EC (+10EF) -18EC (0EF) -23EC (-10EF) -29EC (-20EF) -34EC (-30EF) -40EC (-40EF) -46EC (-50EF) -51EC (-60EF) -57EC (-70EF) -62EC (-80EF) -68EC (-90EF) -96EC (-92EF) 0 15 25 33 40 45 48 53 56 59 62 65 67 68 1.000 1.025 1.040 1.053 1.062 1.070 1.074 1.080 1.083 1.088 1.092 1.095 1.097 1.098