MAINTENANCE 4. Open drain valve (3) and drain plug (4), run the engine at low idle, and flush water through the system for 10 minutes. When doing this, adjust the speed of filling and draining the water so that the radiator is always full. While flushing water through the system, watch carefully that the filler hose does not come out of the radiator filler. 5. After flushing, stop the engine, close drain valves after all the water has drained out. 6. After draining the water, clean with a flushing agent. We recommend use of a genuine Komatsu cleaning agent. For details of the cleaning method, see the instructions given with the cleaning agent.
REMARK Close the cab heater valves before any flushing compounds are circulated through the cooling system. 7. After cleaning, open drain valve (3) and drain plug (4) to drain all the cooling water, then close them and fill slowly with clean water. 8. When the water comes up to near the water filler port, open drain valve (3) and drain plug (4), run the engine at low idle, and continue to run water through the system until clean colorless water comes out. When doing this, adjust the speed of filling and draining the water so that the radiator is always full. While flushing water through the system, watch carefully that the filler hose does not come out of the radiator filler. 9.
When the water is completely clean, stop the engine, close drain valve (3), then wrap with sealing tape and close drain valve (4). 10. Open the after-cooler air drain valves (6). 11. Install the undercover. 3-29