Komatsu — 24.6.5 REPLACE HYDRAULIC TANK BREATHER ELEMENT

MAINTENANCE 24.6.4 CLEAN FRESH/RECIRC AIR FILTERS OF AIR CONDITIONER 1. Remove bolts at the top of the luggage box, then remove bracket (1). 2. Remove the bolts at the bottom of the luggage box, then pull up box (2) to remove. Loosen wing bolt (3), move stopper (4) aside, then pull recirculation air filter (5) up to remove it. Pull fresh air filter (6) to the side (left side of the machine) to remove it. 3. Clean filters (5) and (6) with compressed air. If there is oil on the filter or it is extremely dirty, wash it in a neutral washing agent. After washing it, dry it completely before using it again.

REMARK If the dirt clogging the filter cannot be removed by blowing it with air or washing it in water, replace the filter with a new part. If the filter becomes clogged, the air flow will be reduced, and there will be an abnormal noise from the air conditioner unit. NOTICE As a guideline, the filters should be cleaned every 500 hours, but on dusty job sites, clean the filters more frequently. 24.6.5 REPLACE HYDRAULIC TANK BREATHER ELEMENT WARNING Wait for the oil to cool down before replacing the breather element. When removing the oil filler cap, turn it slowly to release the internal pressure, then remove it carefully. 1.

Remove the cover over the hydraulic tank and remove the oil filler cap (1) at the top of the hydraulic tank. 2. Replace element (1) inside the cap. 3-59