MAINTENANCE NOTICE When the hydraulic breaker is installed, the hydraulic oil deteriorates earlier than in normal bucket digging work. Therefore, replace the hydraulic oil according to the chart at the right. 7. After replacing hydraulic oil and cleaning or replacing filter element and strainer, bleed air from the circuit according to the following procedure. Procedure for Bleeding Air Bleed the air from the various components in the order below (Following steps through 7). 1. Bleeding air from pump a.) Loosen air bleed plug (1) and check that oil oozes out from the air bleeder.
b.) If no oil oozes out, remove the drain hose from the pump case, and add hydraulic oil through drain port (2) to fill the pump case. Oil will come out when the drain hose is removed, so secure the hose at a position higher than the level of the oil in the hydraulic tank. c.) After completing the air bleed operation, tighten air bleed plug (1) and install the drain hose. NOTICE If the drain hose is installed first, oil will spurt out from plug hole. If the pump is operated without filling the pump case with hydraulic oil, abnormal heat will be generated and this may cause premature damage to the pump. 3-72