Komatsu — EVERY 250 HOURS SERVICE

. MAINTENANCE SERVICE PROCEDURE REPLACE POWER TRAIN OIL FILTER ELEMENT WARNING 4 - 53 CHECK, CLEAN ADDITIONAL FUEL STRAINER (If e quipped) 1. Open the in spection cover at the bottom of the fue l tank. 2. Tighten the fuel supply valve , then remove the cap , and c lean the strainer and strainer case The straine r forms one unit w ith the cap. 3. After check ing and cleaning t he strainer, set it in the case, then tighten the 4. After install ing, open the fuel supply valve. The parts and oil are at high tempera ture after the engine is s topped , and may cause serious burns. W ait for the temperature to go d own before s tarting the operatio 1.

Remove to p mounting bolts ( 2) of filter cover (1), t hen us e the bottom hin ge as the fulcrum to open the cover to t he outside. 2. Remove se al (3) installed to