DRESSTA Co. Ltd. TD-40C98/1E — 5.10. ELECTRICAL SYSTEM

SECTION 5 MAINTENANCE Page 30 5.10. ELECTRICAL SYSTEM WARNING! Never check the battery charge by placing a metal object across the terminals. The sparks could cause a battery explosion. Use a voltmeter or hydrometer to measure charge. WARNING! Be sure the electrical system master switch is off when connecting or disconnecting the battery to minimize the chance of sparks and explosion. Maintenance Proper battery maintenance will assure maximum service. Following are a few simple rules: Keep battery cable terminals clean and tight. Keep filler cap vent holes unplugged. Replace worn, cracked, broken or corroded cables. Keep battery fastened securely in frame. NOTE:

Excessive tightening can warp or crack battery case. Maintain the correct battery electrolyte level. Refer to “Electrolyte Level”. Always charge the battery in a ventilated area. Keep the battery clean. Refer to “Cleaning the Battery”. The following precautions must be taken when working around batteries: Use a battery carrier to avoid spilling electrolyte on clothing. Wearing rubber aprons and gloves is advisable. Be careful that tools or other metallic objects do not fall across the battery terminals. Never break a live circuit at the terminals. This could cause sparks. Make sure charger cable clamps or booster leads are clean and making good contact.

If it becomes necessary to prepare electrolyte of a desired specific gravity, always pour the acid into the water. Always turn the charger to the OFF position before connecting or removing charger leads to the battery. When charging a battery, it is recommended that the caps be left on. A damp cloth should be placed on top of the caps. Cleaning the Batteries If the top of a battery is dirty, it may be cleaned with a brush dipped in ammonia or soda solution. Electrolyte Level The electrolyte in each cell must be at the proper level (21 to 27 mm above the plates) at all times to prevent battery failure. Check the level of the electrolyte.

When the electrolyte is below this level, pure distilled water must be added. Never use hydrant water or any water which has been in a metal container. A skilled battery man must never add except acid or electrolyte. Under no circumstances add any special battery solutions or powders. It is especially important to keep the battery at full charge for cold weather operation. Add distilled water to the battery in freezing temperatures only when the engine is to operate for several hours, to thoroughly mix the water and the electrolyte, or damage to the battery may occur.

Charging Fully Discharged Batteries When a machine is not in use for an extended period, the maintenance-free battery can become discharged. For this reason, when a machine will not be used for over 30 days, it is recommended that the negative ground terminal cable be disconnected. Prior to starting up a machine that has been idle, always make a visual inspection of the battery and take an open circuit voltage test. A reading of 12.3 volts (75% of full charge) or less indicates a state of discharge and battery should be charged. TD-40C DRESSTA