DRESSTA Co. Ltd. TD-40C98/1E — 5.13. HYDRAULIC SYSTEM

SECTION 5 MAINTENANCE Page 40 5.13. HYDRAULIC SYSTEM NOTE: Use clean oil from a clean container. Maintain all packaging and fittings so as to prevent leakage. 1. Reinstall the drain plug. Fill the reservoir with lubricant up to the center line of the sight gauge. Refer to 6.8.2. “REFILL CAPACITIES” chart for the quantity oil specified. Reinstall the filler cap. 2. Vent the system. Refer to “VENTING THE SYSTEM”. 5.13.3. SERVICING THE RETURN FILTER AND EQUIPMENT HYDRAULIC CONTROL SYSTEM FILTER NOTE: The hydraulic reservoir does not have to be drained in order to service this filter. NOTE:

If the filters warning light on the instrument panel, remains on at operating oil temperature with the engine running, the filter must be changed. Two hydraulic return filters and one pilot filter change according SCHEDULED MAINTENANCE GUIDE as described below: 1. Park the machine on level ground lower the blade to the ground and stop the engine. Turn the electrical master switch to OFF. 2. With the engine stopped, operate the equipment lever several times in all directions to relieve any pressure. Remove return filters side cover located at R.H. side in front of the hydraulic reservoir, remove all outside dirt from filters. 3. Using a filter wrench remove the spin-on filter.

Wipe the filter base, removing all of the old oil from the seal area. 4. Coat the seal on the new filter element with clean oil. Install the new element by threading it onto the filter base until the seal contacts the base, turn the filter by hand an additional 1/4 to 1/2 turn. Check the oil level in the system as outlined under CHECKING THE OIL LEVEL. Fig. 5.29. Return Filters 1. Hydraulic System Filters 2. Equipment Hydraulic Control System Filter TD-40C DRESSTA