MAINTENANCE SECTION 5 Page 41 5.13. HYDRAULIC SYSTEM 5.13.4. SERVICING THE SUCTION STRAINER Fig.30. Hydraulic Oil Suction Strainer (Inside Hydraulic Reservoir) and Filler Strainer 1. Park the machine on level ground, lower the blade to the ground and stop the engine. Turn the electrical master switch to OFF. With the engine stopped, operate the equipment lever several times to relieve any pressure. Drain the hydraulic system. Refer to CHANGING HYDRAULIC OIL. 2. Remove 3 bolts and remove cover ot hydraulic reservoir. Remove the strainer from the reservoir and discard the O-ring and replace with new. 3. Clean the suction strainer in a nonflammable commercial solvent and dry thoroughly.
Thoroughly clean the interior of the reservoir being sure all particles are removed from the corners. WARNING! Fire hazard – do not use kerosene, diesel fuel or flammable liquids to clean parts. A spark or a flame could cause a fire or an explosion. Use a nonflammable commercial solvent. 4. Install the strainer with new O-ring and connect elbow. Fill the system, refer to CHANGING HYDRAULIC OIL. DRESSTA TD-40C