DRESSTA Co. Ltd. TD-40C98/1E — 5.14. LUBRICATION FITTINGS

MAINTENANCE SECTION 5 Page 43 5.13. HYDRAULIC SYSTEM 5.13.6. VENTING THE HYDRAULIC SYSTEM The hydraulic system has to be vented of air if: The system has been drained and filled hydraulic lines have been disconnected or tightened after noting hydraulic leaks the hydraulic system has been operated with excessively low oil level. 1. Start the engine and run it at low idle speed. Operate all the controls through all positions four or five times so the cylinders are filled with oil and air expelled. 2. Check the oil level as described under CHECKING OIL LEVEL. Repeat this procedure until the fluid level remains at the specified level in the reservoir. 5.14.

LUBRICATION FITTINGS General The following lubrication fittings are to be greased at the intervals indicated on the MACHINE SERVICE GUIDE. brake and throttle linkage (8 fittings) hand steering levers (2 fittings) Fig. 5.33. Hand and Foot Control Linkage Lubrication Fittings Mounted equipment fittings: Lift cylinder trunnion (4 fittings) Blade w/tilt (6 fittings) Blade w/o tilt (7 fittings) DRESSTA TD-40C