DRESSTA Co. Ltd. TD-40C98/1E — 5.15. MOUNTED EQUIPMENT

SECTION 5 MAINTENANCE Page 44 5.14. LUBRICATION FITTINGS Fig. 5.34. Mounted Equipment Fittings Apply grease until clean lubricant is visible. Always use a clean lubricator and wipe dirt from fittings before fresh grease is applied. If grease fails to go through the fitting, determine the cause and correct it. Cross tube (lubrication with lube lines). Apply grease until clean lubricant is visible. The ripper contains 12 lube fittings (ripper w/hydraulic pin puller contains 14 lube fittings). 5.15. MOUNTED EQUIPMENT 5.15.1. COMPLETE BALDE REMOVAL AND INSTALLATION Fig. 5.35. Complete Semi-U/U-Blade If for any reason the complete blade is to be removed from the tractor; proceed as follows: 1.

Place the blade on level ground and block up the ends of the push arms close to the trunnions. This will maintain a proper height for reassembly. TD-40C DRESSTA