DRESSTA Co. Ltd. TD-40C98/1E — 5.15. MOUNTED EQUIPMENT

SECTION 5 MAINTENANCE Page 46 5.15. MOUNTED EQUIPMENT 7. Check if the blade is positioned symmetrically to machine axis. Operating with blade non- symmetrical to machine axis results in damage to the blade. 5.15.1.1. Leveling the Blade 1. Place the lowest corner of the blade on a flat surface. 2. Hold the control lever in position on the side to which the blade is to be lowered until the blade is even along the flat surface. 5.15.1.2. Lower Diagonal Strut Adjustment The diagonal strut stress reliever lever adjustment must be checked occasionally to ensure it is remaining parallel with the back of the blade. Adjust as follows:

With the blade on the ground, remove the pin at the push arm bracket connection. Move the stress reliever lever (3) away from the blade until it is parallel with the back of the blade. Block between the lever (3) and the back of the blade to maintain this parallelism during lower strut adjustment. Remove the four (4) cap screws securing the lower strut cap (5) to the stress reliever lever. Attach a suitable lifting device with sling to the lower strut to support the strut during shimming adjustment. Slide the strut (1) with cap (5) back to disengage the strut ball from the lever socket. Remove all shims (2), which were present and reassembly, the strut into the lever socket.

Install the four cap screws (4) and torque to 400 Nm. Fig. 5.38. Blocking the Stress Reliever Lever Parallel to the Blade 1. Diagonal Strut 2. Shims 3. Stress Reliever Lever 4. Cap Screws 5. Strut Cap TD-40C DRESSTA