DRESSTA Co. Ltd. TD-40C98/1E — 5.18. TRANSMISSION SYSTEM

MAINTENANCE SECTION 5 Page 55 5.18. TRANSMISSION SYSTEM 5.18.4. SERVICING THE SUCTION STRAINER Fig. 5.48. Suction Strainer 1. Remove the operators compartment floor board to gain access to suction strainer located on R.H. side under the board. 2. Remove four bolts and separate the housing from the base. Remove the element with magnets and O-ring. 3. Wash the element and housing in a commercial solvent and dry thoroughly. Replace O-ring. Remove all dirt from the inside of the base using a cloth dampened with solvent. 4. Check that the new O-ring is in place in the groove in the element. Slip the non O-ring end of the element into the housing.

Secure the housing to the base with the hardware previously removed. 5. Start the engine and let it idle for approximately five minutes. During this time, check the strainer for leaks. Correct all leaks no matter how minor. Then check the level in the transmission system as outlined under “CHECKING THE OIL LEVEL”. Reinstall the operators compartment floor board. 5.18.5. SERVICING THE BREATHER NOTE: To prevent dirt from entering the critical areas of the transmission system, keep the breather clean. Replace the breather as indicated when changing oil in the rear frame. The breather is located on the transmission system filler tube. Unscrew the breather from the reducer nipple.

Install the new breather on the nipple. DRESSTA TD-40C