SECTION 5 MAINTENANCE Page 56 5.18. TRANSMISSION SYSTEM Fig. 5.49. Transmission System Breather and Oil Drain Receiver Location 5.18.6. SERVICING TRANSMISSION SCAVENGER STRAINER NOTE: With the transmission system drained after 1000 hours of operation, remove the scavenger oil strainer and clean as described below. 1. To gain access to the oil strainer first removes the transmission guard. 2. Disconnect the transmission scavenger hose from the transmission. Fig. 5.50. Transmission Scavenger Oil Strainer 3. Remove the strainer from the transmission housing. 4. Clean the strainer with a nonflammable commercial cleaning solvent. 5. Install the strainer into the transmission. TD-40C DRESSTA