Komatsu — 250 HOUR SERVICE

OM4010 05/07 Maintenance - Section 4 Lubrication and Service Page 4-9 250 HOUR SERVICE (continued) 6. HYDRAULIC TANK BREATHERS - Remove breathers, disassemble breathers, remove filter element, clean in solvent. Allow to air dry, reas- semble, and install. 7. DIFFERENTIAL CASE - Check oil level. Refer to Lube Key B. 8. DIFFERENTIAL CASE BREATHER - Remove breather. Wash to flush out the dirt from inside the breather. Reinstall after cleaning. 9. FINAL DRIVE CASE - Check oil level in R.H. and L.H. case. Refer to Lube Key B. 10. DRIVE SHAFTS - Inspect drive shafts for any abnormalities: loose joints, worn splines or bearings, abnormal vibrations of the shaft.

Refer to Section F, Drivelines and Adapter . Notify the proper maintenance authority if any discrepancies are found. Refer to Lube Key D. 11. PARKING BRAKE - Measure brake pad for wear and proper thickness. Refer to Section J, Brake System, Brake Circuit Checkout And Adjustment, for proper inspection, procedures, and recommended tools . COMMENTS CHECKED INITIALS