OPERATION LONG-TERM STORAGE Before Storage When putting the machine in storage for a long period (more than one month), do the following procedure. Clean and wash all parts and then store the machine indoors. If the machine must be stored outdoors, select level ground and cover the machine with a sheet. Completely fill the fuel tank; this prevents moisture from collecting inside the tank. Lubricate and change the oil before storage. Apply a thin coat of grease to the exposed portion of the hydraulic cylinder piston rods. Disconnect the negative terminals of the battery. Cover the battery or remove it from the machine and store it separately.
Set the lock lever to the LOCK position to prevent the machine from moving. To prevent corrosion, fill the cooling system with Komatsu genuine Supercoolant (AF-NAC) (density between 30% and 68%). During Storage If it is necessary to perform the rust-prevention operation while the machine is indoors, open doors and windows for ventilation since the engine will be running. Be sure to provide adequate ventilation in order to prevent gas poisoning. During storage, operate and move the machine for a short distance once a month so that a new film of oil coats the moving parts. At the same time, also charge the battery.
When operating the work equipment, wipe off all the grease from the hydraulic cylinder rods. If the machine is equipped with an air conditioner, run the air conditioner for three to five minutes once a month to lubricate all parts of the air conditioner compressor. Always run the engine at low idle when doing this. Check the refrigerant level twice a year. 2-112 WA500-3LK