3. Loosen the knob of priming pump (3), then pump the knob and check that the fuel comes out from air bleed plug (2). OPERATION 4. Tighten air bleed plug (2). Tightening torque: . . . . . . . . . . . 7.8 to 9.8 N•m (69.0 to 86.7 lbf in) 5. Loosen air bleeder (4) of the supply pump. 6. Pump priming pump (3) 90 to 100 times, until no more bubbles come out with the fuel from air bleeder (4). 7. Tighten air bleeder (4). Tightening torque: . . . . . . . . . . . 4.9 to 6.0 N•m (43.4 to 53.1 lbf in) 8. Continue pumping until priming pump (3) becomes stiff. 9. Push the knob of priming pump (3) in and tighten it. 10. Turn the key in the starting switch to the START position and start the engine.
If the engine does not start, repeat the procedure from Step 2. WA500-3LK 2-115