When It Is Impossible to Check Electrolyte Level from Side of Battery MAINTENANCE If it is impossible to check the electrolyte level from the side of the battery or there is no display of the UPPER LEVEL line on the side of the battery, use this procedure to check the level. 1. Remove cap (1) on the top of the battery; look into the filler port; and check the electrolyte level. If the electrolyte level does not reach the sleeve, add distilled water so that the level reaches the bottom of the sleeve (UPPER LEVEL line). 2. Use the following diagram for reference and check if the electrolyte reaches the bottom of the sleeve. 3. Replace cap (1) and tighten it securely.
Remark If water is added above the bottom tip of the sleeve, use a syringe to remove the electrolyte and lower the level to the UPPER LEVEL (UL) line. Neutralize the removed fluid with baking soda (sodium bicarbonate) and then flush it away with a large amount of water, or consult your Komatsu distributor or battery manufacturer. When It Is Possible to Use Indicator to Check Electrolyte Level If it is possible to use an indicator to check the electrolyte level, follow the instructions provided with the indicator. WA500-3LK 3-47