OM3214 Operation - Section 3 Operator Cab and Controls Page 32-21 A5. Service Engine This amber indicator light will illuminate when the Advanced Engine Monitor (AEM) system detects a fault. A warning buzzer will also sound. A6. NOT USED Not currently used. Reserved for future use or options. B5. High Wheel Motor B6. NOT USED Temperature (Optional) When this indicator is illumi- nated and alarm sounds, high wheel motor temperature is indicated. Stop truck, place Selector Switch in NEUTRAL and raise engine RPM to high idle for several minutes to cool wheel motors. If indi- cator does not turn off, notify maintenance personnel. Not currently used. Reserved for future use or options. C6.
NOT USED Not currently used. Reserved for future use or options. C5. Motor Blower OFF The motor blower warning light will flash on and off and an alarm will sound if a malfunction occurs in the cooling air circuit for the alternator and motorized wheels. Stop the truck immediately and notify maintenance personnel if warning light glows. Damage to electrical components may result without proper ventilation of rotating equipment. D6. Service Engine (Cummins) When the keyswitch is turned ON (before starting engine), this amber Service Engine indi- cator light will illuminate for about 2 seconds and then turn off, if no faults are detected in the system.
If this indicator remains ON (or flashes when equipped with Centry™ Fuel Control system), alert maintenance personnel as soon as possi- ble . D5. NOT USED Not currently used. Reserved for future use or options. Komatsu Engines w/Centry™ Fuel Control - This indicator monitors the Centry™ fuel system. During engine operation, if a fault is detected in the system, the light will turn ON and stay on for Warning faults, or it will turn ON and FLASH for more Severe faults that can affect engine operation and require immediate attention. E5. NOT USED Not currently used. Reserved for future use or options.
Warning faults (light ON) are ones that require attention in the near future, but in most conditions will not greatly affect governing performance. Severe faults (light FLASHING) are ones that require immediate attention, because Centry™ governor performance could be significantly affected, resulting in a backup mode of operation . Active fault conditions MUST be corrected as soon as possible. Refer to Lamp Test/Diagnostic Test Switch for additional description of this light's function.