2-14 Inspection after installation 1. Inspect each wiring connection. Note: Check each wiring connection by referring to the charger wiring diagram. 2. Measure the insulation resistance. 3. Measure the no-load secondary voltages. Remove the counterweight (See P11-6) Connect the charger plug to a power supply outlet (with the transformer P1 and N1 cables disconnected), start charging (by pressing the NORMAL ON/OFF switch), and measure the following voltages. “F7” error is displayed when charging is started with either the P1 or the N1 cable of the transformer disconnected for the purpose of measuring the no-load voltage of the transformer, but this is not abnormal.
AC voltage DC voltage Measuring instrument DC 500 V megohmmeter Measurement terminals Each coil terminal−frame Standard: 1 MΩ or more Tester range AC 250 V − AC 500 V Measurement terminals U −V , V −W , W −U 2 2 2 2 2 2 Standard: 50/60(Hz) K47-230C048-413: 53/54 V Other than the above: 54/56 V Tester range 250 VDC Measurement terminals P1 and N1 terminals P1 terminal: (+) probe N1 terminal: (-) probe Standard: 50/60(Hz) K47-227C048-405: 72/75 V K47-230C048-413: 71/73 V K47-260C048-409: 71/74 V