Toyota — TROUBLESHOOTING

2-16 TROUBLESHOOTING When a Diagnosis Error Code Is Displayed Error Code F6-1: Safety timer activated Inspection1 AC input voltage check on the power supply side NG (0V, abnormal voltage dorp or lacking phase) OK (AC200 ~ 220V) AC power supply defect or power failure Inspection2 AC power plug terminal voltage check NG Power cable defect (0V, abnormal voltage dorp or lacking phase) OK (AC200 ~ 220V) Inspection3 Charger timer test NG Display defect OK F7 error Press the NORMAL button and check if the magnetic switch is closed and held in that position. OK (closed and held) NG See "3. The magnetic switch is not closed when the button is pressed." on page 2-24.

Inspection4 DC line fuse continuity check NG Blown fuse ( ҐW ) OK (0 W ) See "4.Charging completes normally but the charge is insufficient." on page 2-24.