Maintenance Section Hydraulic Oil, Return Filter, Strainer & Breather - Check, Clean, Change Hot oil and components can cause personal injury. Do not allow hot oil or components to contact skin. 6. Remove the breather. 7. Wash the breather in clean, nonflammable solvent and dry it. 8. Fill the hydraulic tank. See topic, "Refill Capacities." 9. Install the breather. 10. Remove the floor plate. 11. Remove bolts and filter housing. 12. Remove and discard filter element from filter housing. 13. Clean the filter housing with a clean, nonflammable solvent. 14. Clean the housing base. 15. Insert a new filter element into the filter housing. 16. Inspect the filter housing seal. Replace if necessary.
17. Apply a small amount of clean oil to the filter element seal and housing seal. 18. Install the filter housing with filter to the housing base. Install bolts and tighten 20 to 30 N m (15 to 20 lb ft). Park the lift truck level with the forks lowered, parking brake engaged, transmission in NEUTRAL and the engine stopped. 1. Remove the hydraulic tank drain plug located on the bottom of the frame. Allow the oil to drain in a suitable container. Clean and install the plug. 2. Loosen the bolts of the hydraulic tank cover. 3. Remove the strainer from the tank. 4. Install the new strainer by hand. 5. Install the hydraulic tank cover and fasten the bolts. 174 WARNING