Komatsu — CHECK, CLEAN AND REPLACE AIR CLEANER ELEMENT

MAINTENANCE SERVICE PROCEDURE 3. Direct dry compressed air (less than 0.69MPa (7kg/cm 2 , 99.4PSI)) to the outer element from inside along its folds, then direct it from outside along its folds and again from inside. 1) Remove one seal from the element whenever the element has been cleaned. 2) Replace the outer element if it has been cleaned 6 times repeatedly or used throughout a year. Replace the inner element at the same time. 3) Replace both inner and outer elements when the dust indicator red piston appears soon after installing the cleaned outer element even though it has not been cleaned 6 times. 4) Check inner element mounting nuts for looseness and, if necessary, retighten.

(Tightening torgue 4.9 to 5.9 N•m (0.5 to 0.6 kgf•m, 3.6 to 4.3 lbft)) 4. If small holes or thinner parts are found on the element when it is checked by shining a light through it after cleaning, replace the element. NOTICE When cleaning the element, do not hit or beat it against anything. Do not use an element whose folds or gasket or seal are damaged. 5. Set the new or cleaned outer element and fix wing nut (2). (Tightening torgue of wing nut : 5.9 to 7.9 N•m (0.6 to 0.8 kgf•m, 4.3 to 5.8 lbft)) 6. Replace seal washer (4) or wind nut (2) with new parts if they are broken. 7. Remove vacuator valve (5) and clean with compressed air. After cleaning, install again. 8.

Return the red piston in the dust indicator (1) to its origi- nal position. 4-21