Komatsu — BEFORE STARTING ENGINE

. OPERATION MACHINE OPERATIONS AND CONTROLS OPERATION MACHINE OPERATIONS AND CONTROLS 2. Inspect sight gauge (G) from the small inspection hole right cover. The oil level should be within the range below. Condition A: Within range a Condition B: Within range b excess oil from drain plug (P). REMARK The oil level will vary depending upon the oil temperature. Accordingly, use the following as the guide: Before operation: around L level (Oil temperature 10 to 30 ° C (50 to 86 ° F)) Normal operation: around H level (Oil temperature 50 to 80 ° C (122 to 176 ° F)) 5. Move plate (3) to the center of the cap, then secure with bolt (2). 6. Close cover (1).

3 - 60 in the given NOTICE Do not add oil above the H lin e. This will damage the hydraulic circui t or cause the oil to spurt out. If oil has been added above the H level, stop the upper structure so that the drain plug (P) under the hydra stop the engine and wait for th ulic tank will be between both tracks, e hydraulic oil to cool down, then drain and the 3. When the level is below bolt (2), move plate (3) then add oil through oil the L mark, open soil cover (1), loosen at the top surface of oil filler port (F), filler port (F). 4.

When oil is refilled with t he machine in Condition A, fully extend each cylinder of the b right, then screw the oi and pressurize the hyd oom, arm and bucket as illustrated at l filler cap again after it was removed, raulic tank interior. NOTICE Be sure to pressurize the hydr aulic tank. If it is not pressurized, the pump will suck in air, and this will ad versely affect the equipment.