Hydraulicly Operated Power Lift System on Type 421 55-2 1. Loosen nut for tensioner and remove ten buffer. sioner, also take off sleeve and rubber 2. Remove V-belt. 3. Loosen and disconnect line. 4. Loosen the 4 mounting screws on the base of compressor, take out air compressor with oil pump. 5. Installation is done vice-versa. Remark: After installation, the V-belt should tightened together of a distance of 70 mm. Now tighten front counter nut. be tensioned until the rubber buffer is 6. Fill up hydraulic oil in pump to upper mark of dip stick. 7. Repair pump and air compressor, see job Picture 55-2/1 no. 55-6.
1 = Tension mechanism for V-belt 2 = Swivel point for air compressor mounting bracket B. Remove and install hydraulic cylinder 1. Disconnect hoses on hydraulic cylinder quick couplings. 2. Both pins on frame mounting bracket and eye of shaft to be unlocked by taking out 2 screws with lock ring M 8.