11. Reassembly is done vice-versa. 5. Remove screws on starter housing cover and take off cover. 12. Check starter on test bench. Picture 15-1/2. 6. Remove armature out of housing. 7. Clean brushes with fuel and a clean Never touch the sparkling contact with a file or sand paper, clean mountings with air pressure. cloth. ereas brush 8. Clean collector, if grooves can be seen, turn off a little and polish, also clean grooves between the collector bars other wise short circuit. 9. Check starter pinion, if necessary, renew. 10. Check brushes and brush pressure springs, f necessary, renew. Picture 15-1/2 C. Remove and install magnetic switch Remove: Installation: 1.
Remove ground cable on ground po1 of battery. 5. Check the installation measurement on the magnetic switch and if necessary adjust. See page 15/54-0/1. 2. Disconnect cable 30 and 51 on the connec tion of the magnetic switch. Remove the cable from the field windings to the ma gnetic switch. After the adjustment, the universal fork and the counter nut must be secured with varnish FL 53 V 8. 3. Remove the control cable on the connec tion 50. 6. The rest of the installation is done vice- versa. 4. Remove the cylindrical screws on the cover flange for the drive bearing, unhook the magnetic switch on the engagement leever and remove.