7. Generator trouble in generol are mostly shown by the bright shining indication lamp for ignition. The exact malfunctioning shieled At this should wiper motors of approx. 200 W. consumer, the regulator voltage be within the recommended of the generator can only be destined on a limits. test bench. However, the generator with regulator can be tested while both of them If the voltage is not within this limits, are installed as follows: shut-off engine, pull regulator plug and repeat checking with new regulator. In a Connect voltage meter on U + and D-. Without a switch-on consumer, the regu case the regulator voltage is now correct lator voltage at engine rpm.
of 1500/mm., should be for various types of regulators, between 13.9 to 14.8 V. install the new regulator. If the voltage s still out of the limit recommended change generator. Pay attention for a surrounding tem peratur of the regulator, app. 20 ° C and b Shut-on consumer head lights and wind a load capacity of the battery of 60 %. B. Remove and install generator Remark: Any repair of an alternator should be done 1. Disconnect battery 2. Disconnect wires from generator. Remark: Instead of a cable shoe, a three-fold-plug connection is mounted. in an authorized Bosch Service Station. 3. Remove set screw on bracket of generator, remove V-belt. Picture 15-2/2. 4.
Remove screw on support of generator bracket, take off generator. 5. Installation is done vice-versa, connect cables. Picture 15-2/2 = Set screw for v-bell 2 = Screw of generotor support 3 Generolor support brockel 6. Tension V-belt