mercedes-benz — Mercedes-Benz Unimog 421-411 Service Workshop Manual Volume 1

Exchange Voltage Regulator 15-3 Remarkt To have a continous control wether or not In the most cases the voltage regulator did the generator is working while the engine is failed. Since the regulator can only be repaired running, a control light is mounted on the dash in a Bosch Service Station, change the complete board. . regulator. This check lamp should light when the ignition 1. Disconnect ground cable from battery. key is pushed in and the engine is not running. 2. Disconnect cable on voltage regulator. The moment the engine starts running, the light must go off. This means the generator is 3. Remove regulator. working perfect. Remark:

Is the lamp going on during the vehicle is in operation, that would mean the generator The voltage reguiator is located in the front does not work. The trouble must be looked engine compartment. after at once to avoid a voltage drop in the battery. 4. Installation is done vice-versa.