Bombardier Recreational Products Inc. (BRP) Sea-Doo RXT iS255 GTX LIMITED — Print Preview - C:\DOCUME~1\coderma\LOCALS~1\Temp\.aptcache\smr2009Piranhaen6/tfa03092

Section 02 ENGINE Subsection 07 (PTO HOUSING AND MAGNETO) smr2009-022-101_c STATOR INSULATION TEST 1. Connect adapter to magneto stator connector 2. Leave vehicle harness disconnected smr2009-022-012_a 1. Stator screws 2. Stator Read resistance. Stator Installation For installation, reverse the removal procedure. However, pay attention to the following. NOTE: The position of the stator in the PTO hous- ing is determined by a key on the stator and a notch in the magneto housing. If there is a resistance or continuity to engine ground, the stator coils and/or the wiring is grounded and need to be repaired or replaced. Stator Removal Remove PTO housing, see procedure in this sub- section.

Remove stator cable holding plate from PTO hous- ing. smr2009-022-013_a 1. Notch for stator Place the stator cable rubber grommet in the notch provided in the PTO housing. smr2009-022-011_a TYPICAL 1. Screws 2. Holding plate Remove stator retaining screws. Remove stator from PTO housing. 80 smr2009-022 STATOR INSULATION TEST TERMINAL RESISTANCE @ 20°C (68°F) Any YELLOW wire and engine ground Infinity (open circuit)