Section 02 ENGINE Subsection 08 (LUBRICATION SYSTEM) Disconnect the TOPS switch connector of the blow-by valve. Unscrew and remove the blow-by valve. Blow air through inlet port. Air must flow freely to the outlet port. smr2009-023-023_a smr2009-023-014_a 1. TOPS switch connector 2. Retaining screws Turn valve upside down and blow air again. Air must not flow out. Remove O-ring and V-ring. NOTE: The blow-by valve can not be disassem- bled. If test fails, replace blow-by valve. smr2009-023-024_a Blow-By Valve Installation The installation is the reverse of the removal pro- cedure. However, pay attention to the following. Install the blow-by valve with NEW O-ring and V-ring.
Apply LOCTITE 243 (BLUE) (P/N 293 800 060) on threads of blow-by valve screws. Tighten blow-by valve screws to 9 N•m (80 lbf• in ). Reinstall remaining removed parts. smr2009-023-022_a 1. Blow by valve 2. V-ring 3. O-ring Blow By Valve Inspection If O-ring or V-ring are brittle, cracked or hard, re- place them. If blow-by valve is damaged, replace it. Clean all contact surfaces of blow-by valve. Place a clean rag on valve inlet. OIL COOLER The oil cooler is located below the air intake man- ifold. smr2009-023 111