Bombardier Recreational Products Inc. (BRP) Sea-Doo RXT iS255 GTX LIMITED — Print Preview - C:\DOCUME~1\coderma\LOCALS~1\Temp\.aptcache\smr2009Piranhaen6/tfa03092

Section 02 ENGINE Subsection 09 (COOLING SYSTEM) NOTICE Pure antifreeze will freeze at a higher temperature than the optimal water/antifreeze mix. A blend of 40% antifreeze with 60% dem- ineralized water will improve the cooling effi- ciency. Using water tap instead of demineral- ized water, would contribute to make deposits in cooling system and to reduce antifreeze effi- ciency. This could lead to engine overheating. Cleaning the System NOTICE Cleaning the cooling system as per the following procedure is required when en- gine overheats (assuming everything else is operating normally) or each time coolant is replaced. Drain the cooling system.

Clean thoroughly using the Valvoline Zerex Super Cleaner (or equivalent). Add the cleaning product in coolant expansion tank then fill cooling system with demineralized water. Reinstall cap on coolant expansion tank. Install watercraft in a test basin or ride on a water plane. Start engine and run for approximately 15 minutes. IMPORTANT: Ensure thermostat opens so that the cleaning product flows in ride plate properly. Stop engine and let the cleaning product work for 12 to 16 hours. Thereafter, engine can be run one last time to soak off deposits. Drain and thoroughly rinse the cooling system with clean fresh water. Refill cooling system as described below.

To prevent antifreeze deterioration, always use the same brand. Never mix different brands un- less cooling system is completely flushed and refilled. NOTICE To prevent rust formation or freez- ing condition in cold areas, always replenish the system with 50% antifreeze and 50% dem- ineralized water. Pure antifreeze will freeze at a higher temperature than the optimal wa- ter/antifreeze mix. Always use ethylene glycol antifreeze containing corrosion inhibitors specifically recommended for aluminum en- gines. Using water tap instead of demineral- ized water, would contribute to make deposits in cooling system and to reduce antifreeze effi- ciency. This could lead to engine overheating.

Draining the System WARNING Never drain or refill cooling system when en- gine is hot. Refilling the System Watercraft should be level, engine cold and drain plug removed for refilling. Place a container under drain plug to collect an- tifreeze. Ask someone to pour recommended antifreeze in expansion tank. When antifreeze flows out from the ride plate drain hole, reinstall drain plug. Torque drain plug to 8 N•m (71 lbf• in ). Continue to pour and fill expansion tank between marks. Open seat and remove the rear ventilation box. Remove the coolant expansion tank cap. Install a drain pan underneath the ride plate. Unscrew the drain plug on ride plate. NOTE:

Raising the front of the watercraft will con- tribute to drain the cooling system. smr2009-024-102_a 1. Cooling drain plug Dispose coolant as per local regulations. Do not reinstall drain plug at this time. 118 smr2009-024