Section 02 ENGINE Subsection 09 (COOLING SYSTEM) Thermostat Installation For installation, reverse the removal procedure, paying attention to the following details. Refer to WATER PUMP HOUSING in this subsec- tion. ROTARY SEAL Rotary Seal Inspection Check leak indicator hole for oil or coolant leak. 1. Oil pump cover screws 2. Oil pump cover Remove oil pump cover. Remove outer oil pump rotor. smr2009-024-004_a 1. Leak indicator hole Coolant leaking out of the hole indicates a defec- tive rotary seal. Leaking oil indicates a faulty oil seal. However, if seal is disassembled both parts have to be replaced together.
Rotary Seal Removal Remove WATER PUMP HOUSING, see proce- dure in this subsection. Unscrew the impeller clockwise. 1. Outer oil pump rotor Extract the coolant/oil pump shaft from outside PTO housing cover with a pusher. NOTICE Always unscrew the impeller clock- wise otherwise you can damage the compo- nents. Remove PTO housing Refer to PTO HOUSING AND MAGNETO subsection. Remove oil pump cover screws. 124 smr2009-024