Bombardier Recreational Products Inc. (BRP) Sea-Doo RXT iS255 GTX LIMITED — Print Preview - C:\DOCUME~1\coderma\LOCALS~1\Temp\.aptcache\smr2009Piranhaen6/tfa03092

Section 04 FUEL SYSTEM Subsection 03 (FUEL TANK AND FUEL PUMP) smr2009-031-101_a TEST SETUP mmr2009-121-004_a 1. Y-fitting P/N 293 710 059 2. Check valve P/N 275 500 505 3. Apply compressed air here Slowly apply pressurized air. NOTE: If pressure rises quickly within a few strokes of pump, inlet valve is likely clogged. Refer to INLET CHECK VALVE TEST in this sub- section. When pressure has reached 2.8 kPa - 7.6 kPa (.4 PSI - 1.1 PSI) the pressure relief valve should open preventing a further increase in pressure. When valve opens, pressure must drop at pump gauge. If pressure increases above specification or gauge does not drop to zero, replace outlet valve.

Install a SMALL HOSE PINCHER (P/N 295 000 076) near outlet valve. Install the vacuum/pressure gauge on inlet valve end. smr2009-031-010_a 1. Inlet valve end 2. Vacuum/pressure pump 3. Compressed air supply Set vacuum/pressure pump to pressure. NOTE: To validate outlet hose, connection and valve altogether, a test cap (P/N 293 000 105) or an equivalent hand made plug (such as a capped vent hose) can be installed to the outlet nipple of the valve. 295000076 smr2009-031-012_a 1. Pressure selected smr2009-031 259