Section 04 FUEL SYSTEM Subsection 03 (FUEL TANK AND FUEL PUMP) type hose approved by BRP for ventilation hoses. These hoses available from BRP meet our system requirements and will ensure continued proper and safe operation. WARNING Use of fuel lines other than those recom- mended by BRP may compromise fuel sys- tem integrity. WARNING Whenever removing a hose in the fuel sys- tem, always use new Oetiker clamps at as- sembly. Then, validate fuel tightness by per- forming a fuel tank leak test or a high pres- sure leak test as applicable. F01B05A 1 1. Securing clamp in limited access FUEL PUMP How to Release Fuel Pump Pressure Connect to the latest B.U.D.S.
software, refer to COMMUNICATION TOOLS AND B.U.D.S. SOFT- WARE subsection. Select the Activation tab then the ECM tab. On the RH side of the activation page, click Fuel Press Relief button to release the fuel pressure in the system. Oetiker Clamp Replacement To secure or cut Oetiker clamps on fuel lines, use OETIKER PLIERS (P/N 295 000 070) . 1 F01B03A 1. Cutting clamp smr2009-031-020_a RELEASING FUEL SYSTEM PRESSURE 1. Activation tab 2. ECM tab 3. Click Fuel Press Relief Run engine until it runs out of gas. Fuel Pump Operation Test Disconnect throttle body connector to prevent the throttle actuator to initialize. NOTE:
This step is recommended to minimize noise to validate fuel pump operation. 1. Securing clamp 264 smr2009-031